BExCS11005DPFDC024AB1A1R/C - Đèn còi kết hợp báo động cháy nổ - E2S Việt Nam - Song Thành Công - Xenon Alarm Horn
Ngoài ra công ty Song Thành Công còn cung cấp và phân
phối các dòng thiết bị công nghiệp hóa tự động khác:
|
|
|
|
Eurotherm Vietnam
|
Ordering Code: 2604/VH/121/D4/XX/XX/XX/XX/
XX/XX/Y2/ENG/XX/XX/XX/XX/XX/XX
|
Advance Process
Controller
|
|
Vaisala Vietnam
|
Code: DMT152B1DBB10A000A1A
|
DMT152 Low Dewpoint
Transmitter
|
|
Mechanical connection:
DMT152 Metal NPT 1/2" Thread
|
|
Measurement parameters:
Td/f, ppm
|
|
Analog output Ch1 &
Ch2 + RS-485 as standard: Analog Output 4...20mA
|
|
Analog output parameter
or function for Ch1: Td Range Td-80...+20C -112...+68F
|
|
Analog output parameter
or function for Ch2: Td Range Td-80...+20C -112...+68F ; Output units:
Metric Units
|
|
Pressure Setting for
ppm Calculation: Pressure Not Specified No ppm Output
|
|
Sensor Protection: Mesh
Filter 18um Stainless Steel
|
|
Cable for Analog
Outputs and Power Supply (Port 1): No Cable
|
|
Cable for RS485 Line
and Power Supply (Port 2): No Cable
|
|
Installation
Accessories ONLY for ISO 1/2" Thread: No Accessories
|
|
Special Features:
Plastic Label 1180, 48+3mm, ZZ-Polyest
|
|
Package: Cardboard Box
; User´s Guide: No Manual
|
|
Vaisala Vietnam
|
Code: HMS1102B1A1
|
Humidity and
Temperature Transmitter: HMS110
|
|
Output signals: 4 ...20
mA
|
|
Measured parameter for
channel 1: Td (-40...+60´C)
|
|
Measured parameter for
channel 2: T (-40...+60´C)
|
|
Humidity sensor:
Humicap180R
|
|
User guide:
Multilingual Quick Guide
|
|
Vaisala Vietnam
|
Humidity and
Temperature Transmitter HMT330 8V0A101BCAL110A0AANBAA1
|
Transmitter type :
HMT338 for pressurized pipelines
|
|
Probe cables: 2m
|
|
No Additional
temperature probe
|
|
Calculations: Code
RH+T, With Display
|
|
Power supply: Standard
(10...35V,24VAC)
|
|
Signal output: Analog
Output 4...20mA
|
|
Analog output signals
for Ch1: RH (0...100%RH)
|
|
Analog output signals
for Ch2: Temperature Range 0...+100C
|
|
No Analog output
signals for Ch3
|
|
Output units: Metric
Units
|
|
Option for module slot
1: Relay Module
|
|
Option for module slot
2: no
|
|
Cable bushings: Sealed
Cable Gland M20x1.5
|
|
Transmitter
installation: No Installation Kit
|
|
Humidity sensor:
General purpose HUMICAP180R
|
|
Sensor protection: PPS
Grid with Steel Netting
|
|
Installation kit for
probe: Fitting Body NPT1/2 with No Leak Srew
|
|
User´s Guide HMT330
English
|
|
No PC Accessories; No
Calibration Contract ISO9001 Calibration
|
|
Vaisala Vietnam
|
Low Dewpoint
Transmitter
|
Code: DMT152A1DEC1XA33EA
|
|
Mechanical connection:
DMT152 Metal ISO 1/2" Thread
|
|
Measurement parameters:
Td/f, ppm
|
|
Analog output Ch1 &
Ch2 + RS-485 as standard: Analog Output 4...20mA
|
|
Analog output parameter
or function for Ch1: ppm 0...500ppm
|
|
Analog output parameter
or function for Ch2: Td Range Td-100...0C -148...+32F
|
|
Output units: Metric
Units
|
|
Pressure Setting for
ppm Calculation: Special Pressure Max 50 bar(a)
|
|
Sensor Protection: Mesh
Filter 18um Stainless Steel
|
|
Cable for Analog
Outputs and Power Supply (Port 1): Shielded Cable, 3.0m, 4-pin M8 Female
Straight
|
|
Cable for RS485 Line
and Power Supply (Port 2): Cable 3m 4-pin M8 Female Straight
|
|
Installation
Accessories ONLY for ISO 1/2" Thread: Sampling Cell+Connectors DMT242SC2
|
|
Special Features:
Plastic Label 1180, 48+3mm, ZZ-Polyest
|
|
Hans-Schmidt Vietnam
|
Model: TEM-I
|
Textile Moisture Meter
|
|
Hans-Schmidt Vietnam
|
Model: 50210M
|
Knife electrode (210)
|
|
Hans-Schmidt Vietnam
|
Model: 50213M
|
Surface electrode (213)
|
|
Hans-Schmidt Vietnam
|
Model: 50299M
|
Calibration electrode
(299)
|
Không có nhận xét nào:
Đăng nhận xét